<div style="border-top: none; border-right: none; border-left: none; border-image: initial; border-bottom: 1pt solid windowtext; padding: 0in 0in 1pt; font-size: 14px;" id="isPasted" fr-original-style="mso-element:para-border-div;border:none;border-bottom:solid windowtext 1.0pt; mso-border-bottom-alt:solid windowtext .5pt;padding:0in 0in 1.0pt 0in;"><p style="border: none; padding: 0in; font-size: 14px;" fr-original-style="border:none;mso-border-bottom-alt:solid windowtext .5pt; padding:0in;mso-padding-alt:0in 0in 1.0pt 0in;"><strong fr-original-style="" style="font-weight: 700;">ROLE OBJECTIVE </strong></p><p style="text-align: justify; border: none; padding: 0in; font-size: 14px;" fr-original-style="text-align:justify;border:none;mso-border-bottom-alt: solid windowtext .5pt;padding:0in;mso-padding-alt:0in 0in 1.0pt 0in;">Own end-to-end non-revenue water (NRW) reduction across the assigned projects by setting targets and governance, leading contractors and field teams, operating pressure management, running active leakage control, and verifying savings with auditable evidence and sustained results.</p><p style="text-align: justify; border: none; padding: 0in; font-size: 14px;" fr-original-style="text-align:justify;border:none;mso-border-bottom-alt: solid windowtext .5pt;padding:0in;mso-padding-alt:0in 0in 1.0pt 0in;"><strong fr-original-style="" style="font-weight: 700;">RESPONSIBILITIES</strong></p></div><ul fr-original-style="" style="font-size: 14px;"><li><b style="mso-bidi-font-weight:normal;">NRW Baseline, Targeting, and Benefits Ownership</b></li></ul><li>Build and maintain the NRW baseline (water balance, loss components, confidence grading, and data improvement plan).</li><li>Prioritize zones and DMAs using minimum night flow (MNF), burst history, pressure levels, complaints, and supply constraints.</li><li>Own the benefits tracker (planned vs achieved savings in m³/day and %) and define sustainability criteria (e.g., stable performance over 3–6 months).</li><p style="margin-left: 0.5pt; font-size: 14px;" fr-original-style="margin-left:.5pt;"><b style="mso-bidi-font-weight: normal;">2) Program Governance and Delivery Control (Portfolio Ownership)</b></p><li>Develop the master NRW rollout plan: phases, milestones, dependencies, resource plan, risks, and recovery actions.</li><li>Run governance cadence: weekly field-performance review, monthly steering, and quarterly benefits audit.</li><li>Define standards and quality gates for DMA readiness, commissioning, PRV acceptance, leak repair verification, and handover documentation.</li><p style="margin-left: 0.5pt; font-size: 14px;" fr-original-style="margin-left:.5pt;"><b style="mso-bidi-font-weight: normal;">3) DMA Rollout, Commissioning and Integrity</b></p><li>Define DMA standards (boundaries, valve strategy, inlet flow meters, telemetry points, and critical pressure points).</li><li>Drive commissioning: boundary closure validation, inlet meter verification, stabilization period, and DMA integrity pass/fail criteria.</li><li>Ensure daily monitoring of DMA KPIs (MNF, inlet flow, pressure stability) and translate trends into field actions.</li><p style="margin-left: 0.5pt; font-size: 14px;" fr-original-style="margin-left:.5pt;"><b style="mso-bidi-font-weight: normal;">4) Active Leakage Control (ALC) and Field Execution</b></p><li>Plan and execute leakage operations: screening, pinpointing, repair coordination, and post-repair verification.</li><li>Set and manage productivity norms (survey coverage/day, find-rate, pinpoint accuracy) and enforce QA to prevent rework.</li><li>Manage backlog rules with severity-based response times and tight closure discipline.</li><li></li><p style="margin-left: 0.5pt; font-size: 14px;" fr-original-style="margin-left:.5pt;"><b style="mso-bidi-font-weight: normal;">5) Pressure Management and PRV Operations</b></p><li>Identify candidates for pressure management and implement PRVs, rezoning, and valve control strategies as required.</li><li>Define setpoints and operating philosophy (fixed, modulating, or critical point control where applicable).</li><li>Monitor pressure stability and alarms; correlate pressure changes with bursts, complaints, and leakage run-rate.</li><p style="margin-left: 0.5pt; font-size: 14px;" fr-original-style="margin-left:.5pt;"><b style="mso-bidi-font-weight: normal;">6) Repair Coordination and Closure Discipline</b></p><li>Coordinate repair response and reinstatement quality to reduce repeat leakage and customer complaints.</li><li>Enforce closure workflow: Found → Repaired → Verified → Documented → DMA trend improved.</li><li>Validate savings using MNF trend shifts, inlet flow reduction, and targeted field re-checks when required.</li><p style="margin-left: 0.5pt; font-size: 14px;" fr-original-style="margin-left:.5pt;"><b style="mso-bidi-font-weight: normal;">7) Contractor Management, QA/QC and HSE</b></p><li>Manage internal teams and contractors via SLAs, method statements, non-conformance reporting (NCRs), corrective actions, and recovery plans.</li><li>Enforce HSE in field operations (night work safety, traffic management, and confined-space controls where relevant).</li><li>Maintain audit-ready evidence: GPS-tagged logs, photos, test records, commissioning documents, and as-builts.</li><p style="margin-left: 0.5pt; font-size: 14px;" fr-original-style="margin-left:.5pt;"><b style="mso-bidi-font-weight: normal;">8) Data, Reporting and Decision Support</b></p><li>Ensure accurate field and system data capture (GIS tags, leak type, pipe attributes, PRV settings, repair outcomes).</li><li>Produce actionable dashboards and reports: zone scorecards, DMA health, leakage backlog, PRV stability, and benefits tracker.</li><li></li><div style="border-top: none; border-right: none; border-left: none; border-image: initial; border-bottom: 1pt solid windowtext; padding: 0in 0in 1pt; font-size: 14px;" fr-original-style="mso-element:para-border-div;border:none;border-bottom:solid windowtext 1.0pt; mso-border-bottom-alt:solid windowtext .5pt;padding:0in 0in 1.0pt 0in;"><p style="text-align: justify; border: none; padding: 0in; font-size: 14px;" fr-original-style="text-align:justify;border:none;mso-border-bottom-alt: solid windowtext .5pt;padding:0in;mso-padding-alt:0in 0in 1.0pt 0in;"><strong fr-original-style="" style="font-weight: 700;">Key Deliverables</strong></p></div><li>NRW baseline pack and prioritized DMA pipeline (zones, timelines, expected savings).</li><li>DMA standards plus commissioning and integrity checklist, with stabilization and acceptance criteria.</li><li>Leak detection program plan, weekly field plans, verified leak log with evidence and closure status.</li><li>Pressure management/PRV operating plan (setpoints, control philosophy, alarms, and performance trends).</li><li>Monthly NRW portfolio report covering outcomes, risks, contractor performance, and benefits realization.</li>
Subscribe for free, choose your specializations, and we'll send matching jobs directly to your WhatsApp
Subscribe via WhatsApp, free